Bookbot

Thermoregulation of Sick and Low Birth Weight Neonates

Temperature Control. Temperature Monitoring. Thermal Environment

Parametry

  • 241 stron
  • 9 godzin czytania

Więcej o książce

Over the past 15 years, the population of sick neonates has evolved, with average birthweights dropping to as low as 450g and gestational ages reaching 21-22 weeks. These infants have unique needs that require more complex healthcare, necessitating a shift from previous recommendations based on more mature neonates. This foreword outlines the rationale behind developing new guidelines, focusing on the monitoring and investigation of a baby's thermal condition. Body temperature measurement is crucial for assessing a newborn's thermal state. There is a general consensus that infant body temperature is measured either intermittently with a liquid expansion thermometer or continuously via rectal or axillary sensors. However, rectal temperature may not accurately reflect core temperature, with potential differences of up to 2°C. Such discrepancies can lead to misjudgments in patient assessment; for instance, cold lower limbs can cause venous blood returning from the legs to cool, resulting in a rectal temperature that is significantly lower than core temperature. Research has also indicated that rectal temperature readings can vary based on the depth of sensor insertion.

Zakup książki

Thermoregulation of Sick and Low Birth Weight Neonates, Jochim Koch Albert Okken

Język
Rok wydania
1995
Oprawa
(twarda)
Jak tylko się pojawi, wyślemy Ci wiadomość e-mail.

Metody płatności

Nikt jeszcze nie ocenił.Oceń

Tytuł
Thermoregulation of Sick and Low Birth Weight Neonates
Podtytuł
Temperature Control. Temperature Monitoring. Thermal Environment
Język
angielski
Wydawca
Springer
Rok wydania
1995
Oprawa
twarda
Liczba stron
241
ISBN10
3540601694
ISBN13
9783540601692
Seria
Opis
Over the past 15 years, the population of sick neonates has evolved, with average birthweights dropping to as low as 450g and gestational ages reaching 21-22 weeks. These infants have unique needs that require more complex healthcare, necessitating a shift from previous recommendations based on more mature neonates. This foreword outlines the rationale behind developing new guidelines, focusing on the monitoring and investigation of a baby's thermal condition. Body temperature measurement is crucial for assessing a newborn's thermal state. There is a general consensus that infant body temperature is measured either intermittently with a liquid expansion thermometer or continuously via rectal or axillary sensors. However, rectal temperature may not accurately reflect core temperature, with potential differences of up to 2°C. Such discrepancies can lead to misjudgments in patient assessment; for instance, cold lower limbs can cause venous blood returning from the legs to cool, resulting in a rectal temperature that is significantly lower than core temperature. Research has also indicated that rectal temperature readings can vary based on the depth of sensor insertion.